Estimate the heat pump capacity for a Québec home
Quick calculation in 4 answers
Detailed calculation (advanced) → Detailed costs and savings →
Estimate only. Capacity: area × 16 to 20 BTU/h per sq ft (Hydro-Québec benchmarks), adjusted for climate and insulation (method). Savings: the site’s scenario for Hydro-Québec’s average house (assumptions). This is not a sizing calculation; the detailed calculation picks up your answers.
Optional: request up to 2 quotes from RBQ-licensed installers.
This site explains, in plain terms, how a heat pump is sized and which rebates exist in 2026–2027. No ads and no affiliate links; an optional link to the quote-request form appears after the result. The tool below gives an order of magnitude, not a purchase recommendation.
What size heat pump for a 1,500 sq ft house in Québec?
Hydro-Québec’s rule of thumb (about 12,000 BTU/h of cooling per 750 sq ft) gives a ballpark of about 24,000 BTU/h for a 1,500 sq ft house (estimate only). The site’s estimator gives 24,000–30,000 BTU/h in Montréal, 26,000–33,000 in Québec City and 28,000–34,000 in Saguenay (average insulation, 8 ft ceiling). For the final choice, ask the RBQ-licensed contractor for a room-by-room load calculation (CSA F280). (source: Hydro-Québec)
Guide: how many BTU for my house? (Hydro-Québec rules of thumb, heating or cooling, insulation, CSA F280, questions to ask the installer).
Estimator with options (ceiling height, installation type)
Estimate only. Method: floor area × 16 to 20 BTU/h per sq ft (two Hydro-Québec benchmarks), adjusted for climate, ceiling height and insulation (method). This is not a sizing calculation. For the final choice, ask your installer for a room-by-room heat load calculation (for example to the CSA F280 standard).
Optional: request up to 2 quotes from RBQ-licensed installers.
Get up to 2 quotes from RBQ-licensed installers (optional)
Free, no obligation. The calculator works without this form. Your request comes to us first; we only forward it to companies in your region if you tick the consent box.
This site may be paid by the installers it forwards requests to; this does not affect the calculations. How this site is funded
What heat pump size for 1,000, 1,500 or 2,000 sq ft?
Results of the estimator above, in BTU/h, for average insulation and an 8 ft ceiling. For 1,500 sq ft, the low end of the range is 21% higher in Sept-Îles than in Montréal.
| Location (ECCC DD) | 1,000 sq ft | 1,500 sq ft | 2,000 sq ft |
|---|---|---|---|
| Montréal (4,363 DD) | 16,000–20,000 | 24,000–30,000 | 32,000–40,000 |
| Québec City (5,141 DD) | 17,000–22,000 | 26,000–33,000 | 35,000–44,000 |
| Saguenay (5,636 DD) | 18,000–23,000 | 28,000–34,000 | 37,000–46,000 |
| Sept-Îles (6,196 DD) | 19,000–24,000 | 29,000–36,000 | 39,000–48,000 |
Site calculation: same code as the estimator (area × 16 to 20 BTU/h per sq ft, climate factor, average insulation × 1.00, 8 ft ceiling), rounded to the nearest thousand. DD = heating degree-days below 18 °C, ECCC 1981–2010 normals. Ballpark only, not a CSA F280 calculation.
How does the estimator calculate capacity?
Floor area × 16 to 20 BTU/h per sq ft (two Hydro-Québec benchmarks), adjusted for climate, ceiling height and insulation.
- Base: area × 16 to 20 BTU/h per sq ft, based on the two Hydro-Québec guidelines above.
- Climate: factor = 1 + 0.5 × (locality HDD ÷ Montréal HDD − 1). Degree-days come from ECCC 1981–2010 climate normals (open data). The 0.5 weighting is a site-estimated factor : degree-days measure annual energy, not peak capacity, so we apply only half the difference. Example: Sept-Îles (6,196 HDD) gives 1.21; Montréal gives 1.00.
- Design temperature: shown for the selected location (NBC 2020, Table C-2, January 2.5%) as a reference; it does not change the calculated range. See the table of Québec design temperatures. For a more detailed calculation, wall by wall and level by level, use the heat-loss calculator.
- Height: × height ÷ 8 ft (simple physics: volume is proportional to height; 8 ft by default).
- Insulation: good 0.90 · average 1.00 · poor 1.15. Site-estimated factor, deliberately modest: we found no official coefficient; NRCan and Québec.ca guides only say that insulation and airtightness reduce needs.
- Installed cost: wall unit $3,000 to $6,000, multi-zone $6,000 to $12,000, central $8,500 to $17,000 (BranchéQC, private source; this site’s reference: 2026 prices). Scope: for a wall unit, BranchéQC includes the equipment, refrigerant piping, a dedicated 240 V circuit, labour and the municipal permit; an electrical panel upgrade is extra (BranchéQC guide, updated June 25, 2026). For a central system, cost depends mostly on the condition and adaptation of existing ductwork. Protégez-Vous observed a $9,841 gap between quotes for the same house in Outaouais (source): get at least 3 quotes.
- Rebate: LogisVert pays $50 (ENERGY STAR) or $120 (cold climate) per 1,000 BTU/h at −8 °C, up to $6,700 (Hydro-Québec). Capacity at −8 °C is lower than nominal capacity. Illustrative scenario: low end of the range × 70% for a cold-climate model: ENERGY STAR cold-climate certification requires at least 70% of nominal capacity at −15 °C (ENERGY STAR); applying that floor at the milder −8 °C is a site-estimated assumption. For a standard ENERGY STAR model: × 45%, site-estimated based on the minimum at −15 °C in ENERGY STAR’s “Most Efficient” criteria (source), which does not apply to all models. The actual rebate is set by the −8 °C capacity listed for your model (Hydro-Québec’s list or the manufacturer’s spec sheet): check it in Hydro-Québec’s list of efficient heat pumps.
- Multi-zone: suggested split into common head sizes (6,000, 9,000, 12,000, 18,000 BTU/h) that add up to the range. Site-estimated split : the real split depends on the rooms and must be confirmed by the installer.
Before choosing a model: how to evaluate a heat pump (capacity at −15 °C and −25 °C, COP, HSPF2, NEEP, ENERGY STAR, LogisVert and AHRI lists) · quick heat-loss estimate.
Frequently asked questions
How many BTU per sq ft do you need in Quebec?
Hydro-Québec publishes a rule of thumb of about 12,000 BTU/h of cooling per 750 sq ft (about 16 BTU/h per sq ft). For heating, the need depends on climate, insulation and ceiling height; a CSA F280 load calculation remains the reference.
Can I rely on this site’s estimator alone?
Not for a purchase decision alone: it is an indicative range. Have sizing and price confirmed by a contractor with an RBQ licence.
Where can I find prices, annual costs and rebates?
See 2026 installed prices, the cost analysis and the 2026–2027 rebates.
See also: heat pump prices in Québec in 2026 · the cost and payback analysis · heat pump rebates in 2026–2027.