Estimate the heat pump capacity for a Québec home

Quick calculation in 4 answers

Detailed calculation (advanced) → Detailed costs and savings →

Estimate only. Capacity: area × 16 to 20 BTU/h per sq ft (Hydro-Québec benchmarks), adjusted for climate and insulation (method). Savings: the site’s scenario for Hydro-Québec’s average house (assumptions). This is not a sizing calculation; the detailed calculation picks up your answers.

Optional: request up to 2 quotes from RBQ-licensed installers.

Independent site. No ads, no affiliate links, no cookies without your consent. Every figure links to its source. The optional quote-request form may earn the site revenue; it does not affect the calculations (how this site is funded).

This site explains, in plain terms, how a heat pump is sized and which rebates exist in 2026–2027. No ads and no affiliate links; an optional link to the quote-request form appears after the result. The tool below gives an order of magnitude, not a purchase recommendation.

What size heat pump for a 1,500 sq ft house in Québec?

Hydro-Québec’s rule of thumb (about 12,000 BTU/h of cooling per 750 sq ft) gives a ballpark of about 24,000 BTU/h for a 1,500 sq ft house (estimate only). The site’s estimator gives 24,000–30,000 BTU/h in Montréal, 26,000–33,000 in Québec City and 28,000–34,000 in Saguenay (average insulation, 8 ft ceiling). For the final choice, ask the RBQ-licensed contractor for a room-by-room load calculation (CSA F280). (source: Hydro-Québec)

Guide: how many BTU for my house? (Hydro-Québec rules of thumb, heating or cooling, insulation, CSA F280, questions to ask the installer).

Estimator with options (ceiling height, installation type)

HDD = heating degree-days below 18 °C, Environment and Climate Change Canada 1981–2010 normals. Abitibi and Nord-du-Québec: no current normals found, pick the most similar locality.
Simple physics adjustment: capacity is multiplied by height ÷ 8 (air volume is proportional).

Estimate only. Method: floor area × 16 to 20 BTU/h per sq ft (two Hydro-Québec benchmarks), adjusted for climate, ceiling height and insulation (method). This is not a sizing calculation. For the final choice, ask your installer for a room-by-room heat load calculation (for example to the CSA F280 standard).

What heat pump size for 1,000, 1,500 or 2,000 sq ft?

Results of the estimator above, in BTU/h, for average insulation and an 8 ft ceiling. For 1,500 sq ft, the low end of the range is 21% higher in Sept-Îles than in Montréal.

Indicative capacity in BTU/h (site calculation, this page’s estimator)
Location (ECCC DD)1,000 sq ft1,500 sq ft2,000 sq ft
Montréal (4,363 DD)16,000–20,00024,000–30,00032,000–40,000
Québec City (5,141 DD)17,000–22,00026,000–33,00035,000–44,000
Saguenay (5,636 DD)18,000–23,00028,000–34,00037,000–46,000
Sept-Îles (6,196 DD)19,000–24,00029,000–36,00039,000–48,000

Site calculation: same code as the estimator (area × 16 to 20 BTU/h per sq ft, climate factor, average insulation × 1.00, 8 ft ceiling), rounded to the nearest thousand. DD = heating degree-days below 18 °C, ECCC 1981–2010 normals. Ballpark only, not a CSA F280 calculation.

12,000 BTU/h per 750 sq ft≈ 16 BTU/h per sq ftHydro-Québec cooling rule of thumb (source)
15,000 BTU/h per 750 sq ft= 20 BTU/h per sq ftHydro-Québec buying guideline (source)
Important: this is an estimate. Actual capacity must be confirmed by a load calculation (CSA F280 method) by a contractor licensed by the Régie du bâtiment du Québec (RBQ).
Beware of fraud: Hydro-Québec says it does no telephone or door-to-door solicitation for LogisVert (source). If you receive a suspicious solicitation, Hydro-Québec suggests filing a complaint with theOffice de la protection du consommateur (source).

How does the estimator calculate capacity?

Floor area × 16 to 20 BTU/h per sq ft (two Hydro-Québec benchmarks), adjusted for climate, ceiling height and insulation.

  1. Base: area × 16 to 20 BTU/h per sq ft, based on the two Hydro-Québec guidelines above.
  2. Climate: factor = 1 + 0.5 × (locality HDD ÷ Montréal HDD − 1). Degree-days come from ECCC 1981–2010 climate normals (open data). The 0.5 weighting is a site-estimated factor : degree-days measure annual energy, not peak capacity, so we apply only half the difference. Example: Sept-Îles (6,196 HDD) gives 1.21; Montréal gives 1.00.
  3. Design temperature: shown for the selected location (NBC 2020, Table C-2, January 2.5%) as a reference; it does not change the calculated range. See the table of Québec design temperatures. For a more detailed calculation, wall by wall and level by level, use the heat-loss calculator.
  4. Height: × height ÷ 8 ft (simple physics: volume is proportional to height; 8 ft by default).
  5. Insulation: good 0.90 · average 1.00 · poor 1.15. Site-estimated factor, deliberately modest: we found no official coefficient; NRCan and Québec.ca guides only say that insulation and airtightness reduce needs.
  6. Installed cost: wall unit $3,000 to $6,000, multi-zone $6,000 to $12,000, central $8,500 to $17,000 (BranchéQC, private source; this site’s reference: 2026 prices). Scope: for a wall unit, BranchéQC includes the equipment, refrigerant piping, a dedicated 240 V circuit, labour and the municipal permit; an electrical panel upgrade is extra (BranchéQC guide, updated June 25, 2026). For a central system, cost depends mostly on the condition and adaptation of existing ductwork. Protégez-Vous observed a $9,841 gap between quotes for the same house in Outaouais (source): get at least 3 quotes.
  7. Rebate: LogisVert pays $50 (ENERGY STAR) or $120 (cold climate) per 1,000 BTU/h at −8 °C, up to $6,700 (Hydro-Québec). Capacity at −8 °C is lower than nominal capacity. Illustrative scenario: low end of the range × 70% for a cold-climate model: ENERGY STAR cold-climate certification requires at least 70% of nominal capacity at −15 °C (ENERGY STAR); applying that floor at the milder −8 °C is a site-estimated assumption. For a standard ENERGY STAR model: × 45%, site-estimated based on the minimum at −15 °C in ENERGY STAR’s “Most Efficient” criteria (source), which does not apply to all models. The actual rebate is set by the −8 °C capacity listed for your model (Hydro-Québec’s list or the manufacturer’s spec sheet): check it in Hydro-Québec’s list of efficient heat pumps.
  8. Multi-zone: suggested split into common head sizes (6,000, 9,000, 12,000, 18,000 BTU/h) that add up to the range. Site-estimated split : the real split depends on the rooms and must be confirmed by the installer.

Before choosing a model: how to evaluate a heat pump (capacity at −15 °C and −25 °C, COP, HSPF2, NEEP, ENERGY STAR, LogisVert and AHRI lists) · quick heat-loss estimate.

Frequently asked questions

How many BTU per sq ft do you need in Quebec?

Hydro-Québec publishes a rule of thumb of about 12,000 BTU/h of cooling per 750 sq ft (about 16 BTU/h per sq ft). For heating, the need depends on climate, insulation and ceiling height; a CSA F280 load calculation remains the reference.

Can I rely on this site’s estimator alone?

Not for a purchase decision alone: it is an indicative range. Have sizing and price confirmed by a contractor with an RBQ licence.

Where can I find prices, annual costs and rebates?

See 2026 installed prices, the cost analysis and the 2026–2027 rebates.

See also: heat pump prices in Québec in 2026 · the cost and payback analysis · heat pump rebates in 2026–2027.